RG11 Plenum Coax Cable - CCS - Black - 1000 FT

Part no. 80-110-525 BK:1000

75 Ohm | 14 AWG | Shielded | PVC | CMP Rated | Copper Clad Steel Conductor | RoHS Compliant

Quantity Discount Pricing
1-1 2-4 5-9 10-14 15+
$2,583.33 $2,513.51 $2,447.37 $2,384.62 $2,325.00
Quantity Discount Pricing
1 2 - 4 5 - 9 10 - 14 15+
$2,583.33 $2,513.51 $2,447.37 $2,384.62 $2,325.00

The RG11 Plenum coaxial cable is typically used for cable or satellite service. RG11 has an imdedance of 75 ohms and is used for the longer runs or backboning premise wiring. This RG11 Plenum cable features a solid 14 AWG copper clad steel center conductor with a 60% aluminum braid and 100% aluminum foil shield. Plenum cables are made of a low-smoke CMP jacket. This cable is to be run in drop ceilings or plenum air spaces such as non-ducted HVAC air returns.


  • Priced per ft.
  • RG11
  • Plenum rated
  • Impedance - 75 ohm
  • Copper clad steel center conductor
  • Commscope #2285V
Features & Specs
Cable Type The type of cable described? RG11
Impedance Impedance of cable? 75 ohms
Center Conductor The type of material used in the center conductor of the cable?? Bare Copper Covered Steel (BCCS)
Center Conductor Diameter Diameter of center conductor in inches? 1.63 mm
Dielectric Material used as dielectric in the cable?? Solid PE (Polyethylene)
Jacket Material The type of material used in the jacket of the cable? Plenum
Cable Diameter Diameter in inches of cable? 10.5 mm
Minimum Bend Radius The minimum bend radius before the cable may be damaged? 114.3 mm
Operating Temperature Range Range of temperature the cable is designed to withstand? -4/+176°F
REVIEW SUMMARY for RG11 Plenum Coax Cable - CCS - Black - 1000 FT
No reviews for this product

Q: When should an RG11 cable be used?

A: An RG11 cable should be used in longer runs. Typically, anything over 250ft.

Q: What is the maximum distance for RG11 cable?

A: RG11 cable should not exceed 500ft

Q: What does plenum rated mean?

A: Plenum (CMP) is a rating that is given to cables that have passed a stringent burn test and are able to be run through plenum air spaces. Plenum air spaces include drop ceilings and non-ducted HVAC air returns.

Q: What is a flooded cable?

A: Flooded RG11 direct burial cable uses a water blocking gel to protect the cable from water infiltration, even if the cable has a minor cut in the outer jacket. Flooded cable is typically used for direct burial outdoor applications.

Q: Can ShowMeCables make a custom cable with Low Loss cable?

A: Yes, to get an instant quote please use our Custom Cable Calculator. If you would like to contact to a representative please email us at sales@showmecables.com or by phone at 1-888-519-9505.