Belden 1585A Cat5e UTP Solid Plenum - Black - 1000 FT

Part no. 85-535-320 BK

CMP rated cable. Belden brand. Suitable for long runs and installation in plenum air spaces.

Quantity Discount Pricing
1 2 - 4 5 - 9 10 - 14 15+
$399.95 $394.37 $388.89 $383.56 $378.38
QTY Each Total
X $399.95


Belden 1585A Cat5e UTP Solid Plenum is a CMP rated cable. The cable is designed to be used in plenum air-return spaces, such as drop ceilings. Plenum cable is commonly used for structured cabling projects such as vertical, horizontal, or backbone systems. Belden 1585A features a Flamarrest low smoke PVC jacket. Internally the cable consisted of 4 pair 24 AWG bare copper conductors. This bulk cable is in an easy-pull box and can be measured and cut to exact distances, then terminated to a connector, jack, or patch panel.

Features:

  • Jacket Flamarrest Low Smoke Polyvinyl Chloride (LS-PVC)
  • 24 AWG Solid Bare Copper Conductors
  • Tested up to 200 MHz
  • Meets Cat5e Standards
  • RoHS Complaint
  • ETL Listed
  • CMP Rated

"Plenum" refers to the highest fire-resistance standard of the National Electrical Code (NEC). Many local building codes specify that plenum-rated cables must be used in plenum air-return spaces, such as drop ceilings. These cables have special fire-retardant jackets, but  there is no performance difference between plenum and non-plenum cables. Because plenum cables meet the highest standard, they can be used in any application, but due to  price differences it makes sense only to use plenum cables when necessary.

REVIEW SUMMARY for Belden 1585A Cat5e UTP Solid Plenum - Black - 1000 FT
No reviews for this product
1

Q: What is the maximum length for a Cat5e cable?

A: The maximum length for a Cat5e cable run is 100 meters (328 feet). If longer runs are required, the use of active hardware such as a repeater or switch is necessary.

Q: What is the difference between solid and stranded cable?

A: Solid Cat5e is a 4-pair cable. Within each of the 8 individual wires there is a solid piece of wire covered by a PVC jacket. Because of the solid core of these cables they will be more rigid than stranded cable, but can carry a stronger signal than stranded wire. Solid cable also has the ability to be punched down in to jacks, patch panels, and 66 blocks.

Stranded Cat5e is a 4-pair cable as well. Within each of the 8 individual wires there are multiple tiny stands of smaller gauge wire that are held together by a PVC jacket. Because this cable is made with smaller strands of cable it is more flexible than solid core wire. Stranded Cat5e is typically use for short patch cables. Stranded wire cannot be punched down.

Q: What is shielded Cat5e cable?

A: Shielded Cat5e cable is used for increased protection from interference and crosstalk. It is typically used in electrical noisy environments. Common sources of interference are radio towers, high-powered electrical conduit, fluorescent lighting, or any other device emitting electro-magnetic or radio frequency signals.

Q: What’s the difference between the UL and ETL listed Marks?

A: Both marks demonstrate that the product that bears it has met the minimum requirements of widely accepted product safety standards as determined through the independent testing of a Nationally Recognized Testing Laboratory (NRTL). The only real difference between the Marks is in the service, and services, of the testing laboratory behind them.

Both the ETL and UL Listed Marks are recognized by local inspectors and Authorities Having Jurisdiction (AHJs) throughout North America and also in some areas of South America.

Q: What is a flooded cable?

A: Flooded Cat5e cable uses a water blocking gel to protect the cable from water infiltration, even if the cable has a minor cut in the outer jacket. Flooded cable is typically used for direct burial outdoor applications.

Q: Will our Cat5e cable support Power over Ethernet (POE)?

A: Yes, all of our Cat5e will support Power over Ethernet.

Q: What does plenum rated mean?

A: Plenum (CMP) is a rating that is given to cables that have passed a stringent burn test and are able to be run through plenum air spaces. Plenum air spaces include drop ceilings and non-ducted HVAC air returns.